Metric Belleville (DIN 6796)

Bolted joints will work loose due to a loss of preload. This can be caused by permanent set in any part of the assembly. Belleville washers will counteract this loosening by increasing the axial compliance of the joint.

The load values listed in the table below are according to the calculated theoretical load curve based on the dimensions and material for each part number.

Part NumberOD
in
ID
in
THICK
in
DISH
in
HEIGHT
in
Load 100%
lb
OD
mm
ID
mm
THICK
mm
DISH
mm
6796-20.1970.0870.0160.0080.02414252.20.40.2
6796-2.50.2360.1060.020.0090.02821462.70.50.22
6796-30.2760.1260.0240.010.03331073.20.60.25
6796-3.50.3150.1460.0310.010.04258883.70.80.26
6796-40.3540.1690.0390.0120.051106494.310.3
6796-50.4330.2090.0470.0140.0611442115.31.20.35
6796-60.5510.2520.0590.020.0792423146.41.50.5
6796-70.6690.2910.0690.0220.0912815177.41.750.55
6796-80.7090.3310.0790.0240.1024208188.420.6
6796-100.9060.4130.0980.0280.12658152310.52.50.7
6796-121.1420.5120.1180.0370.1568513291330.95
6796-141.3780.5910.1380.0450.1831104635153.51.15
6796-161.5350.6690.1570.0490.20714522391741.25
6796-181.6540.7480.1770.0510.2281881442194.51.3
6796-201.7720.8270.1970.0550.25224544452151.4
6796-221.9290.9060.2170.0610.2783058849235.51.55
6796-242.2050.9840.2360.0690.30533587562561.75
6796-272.3621.1020.2560.0730.3294008260286.51.85
6796-302.7561.220.2760.0870.36242776703172.2

lo(max) = height as delivered
lo(min) = height after initial flattening

 

Scroll to Top